Sump Integrity Testing

Questions Answered: Containment Sump Integrity Testing in Fueling Facilities

For the first time in more than 25 years, the EPA has revised its underground storage tank (UST) regulations. The updated regulations included multiple new regulatory requirements including, among others, mandatory 30-Day walkthrough inspections and required Class A, B and C Operator Training. One of the most substantive changes in the area of operational and maintenance requirements is related to Spill Prevention and Containment Sump Testing or more commonly known as ‘Sump Integrity Testing’. The purpose of which is designed to reduce the incidence and impact of the more than 6,000 releases discovered annually from USTs. The following is a guide to help shed light to the requirements and the expectations for facility owners.

Read More

We are now Suffolk County Tank & Line Testing Certified!

We’re very excited to announce that Henrich is now certified to provide Tank and Line testing services in Suffolk County. The Alert 8200 is the only tank tightness testing method approved by the Suffolk County Department of Health Services.

Read More

Tank Compliance Cheat Sheet

Knowing whether or not your tank is regulated is the first place to start. The new regulations offer new rules for determining if your tank is regulated and what regulations apply. Some key questions include:

Before you get started….

Read More

What is Class A, B and C Operator Training?

The federal Energy Policy Act of 2005 made UST operator training mandatory for states receiving funding from the Environmental Protection Agency (EPA).  In addition, section 1524 of the Energy Policy Act established the basic operator classes and definitions and tasked the EPA, in cooperation with states, with developing operator training guidelines.

What is a Class A Operator?

Class A operators:

  • Manage resources and personnel;
  • Maintain compliance with federal, state, and local regulations;
  • Ensure that required records are kept; and
  • Ensure that operators at the facility are trained to respond to releases, spills, and other emergencies.

Read More

Release Detection Testing

Beginning on October 13, 2018 owners and operators must test electronic and mechanical components of their release detection equipment for proper operation at least annually using one of the following options:

  • Manufacturer’s instructions
  • A code of practice developed by a nationally recognized association or independent testing laboratory
  • Requirements developed by the implementing agency

Read More

Spill Prevention and Containment Sump Testing

Beginning on October 13, 2018 owners and operators must meet one of the following for spill containment equipment and for containment sumps used for piping interstitial monitoring:

Option 1: Spill prevention and containment sump equipment is double walled and the integrity of both walls is monitored at least as frequently as in the walk through inspection requirement (typically every 30 days for spill buckets but it may be longer if the facility receives infrequent deliveries, and annually for containment sumps).

Read More